Jetfans · Kyiv, Ukraine

Wolter. Made in Germany — working worldwide

Jet fan ventilation and smoke extraction systems for car parks, shopping centres and residential complexes: Wolter equipment, system design and CFD modelling.

Wolter jet fan mounted under a ceiling
Made in Germany
  • 14projects in Ukraine
  • 300/400 °Csmoke extraction, 120 min
  • 2 factoriesin Germany
  • DIN EN ISOcertified quality

What we do

From equipment selection to system verification

Ventilation equipment

Jet and axial fans for ventilation and smoke extraction, plus Wolter duct, roof and centrifugal fans and control components.

Products

System design

Equipment selection and design of jet fan ventilation and smoke extraction systems for car parks, shopping centres, office buildings and residential complexes.

Discuss your project

CFD modelling

Computer simulation of airflow, temperature and smoke spread to check how the system will perform while it is still on paper.

Modelling examples

How jet fan car park ventilation works

Compact jet fans replace bulky ductwork under the ceiling. Wolter supplies the complete system: fans, sensors and controls that work as one.

Underground car park at the GREAT residential complex
Underground car park, GREAT residential complex, Kyiv
  1. Supply air

    Fresh air enters the car park through supply fans or open inlets.

  2. Jet fans

    Jet fans mounted under the ceiling create a directed airflow that carries air towards the extract zone.

  3. Extract

    Extract fans remove polluted air and, in a fire, take the smoke out by the shortest route.

  4. Sensors & controls

    The system adjusts its operating mode on its own and keeps smoke from spreading into neighbouring fire zones.

  • No ductwork: more headroom and a brighter, more open space
  • Installation, running and maintenance usually cost less than a ducted system
  • Escape routes stay clear of smoke for longer
  • Smoke exhaust fans tested to EN 12101-3 (classes F300 and F400)

Portfolio

Our projects in Ukraine

Buildings where jet fan ventilation systems and Wolter equipment have been installed.

  • UNIT.City innovation park, Kyiv
    Innovation park

    UNIT.City, UNIT.Home

    KAN Development

  • Render of White Lines residential complex at dusk, Kyiv
    Residential

    White Lines

    A-Development

  • Render of Creator City residential complex, Kyiv
    Residential

    Creator-City

    Creator-Bud

  • Render of GREAT residential complex by the Dnipro, Kyiv
    Residential

    GREAT

    Stolytsia / Riel / IB Alliance

  • Nova Anhliia residential complex, Kyiv
    Residential

    Nova Anhliia

    Royal House Group

  • Blockbuster Mall main entrance, Kyiv
    Shopping mall

    Blockbuster Mall

    Mandarin

    2 car parks
  • Render of OK’LAND residential complex, Kyiv
    Residential

    OK’LAND

    Stolytsia / Riel

  • Retroville shopping mall in the evening, Kyiv
    Shopping mall

    Retroville

    Unibep / Stolytsia

  • Render of the Ocean Mall atrium, Kyiv
    Shopping mall

    Ocean Mall

    Mandarin

  • Render of Taryan Towers, Kyiv
    Residential

    Taryan Towers

    Taryan Group

  • Nikolsky shopping mall at night, Kharkiv
    Shopping mall

    Nikolsky

    Budhouse Group

  • MAG.NETT business centre, Kyiv
    Office centre

    MAG.NETT

    Frantsuzkyi Kvartal

  • Respublika Park shopping mall, Kyiv
    Shopping mall

    Respublika Park

    KAN Development

  • Sports

    Kyiv Velodrome

    Kyiv

Worldwide

Wolter equipment runs at landmark sites across Europe

  • Allianz ArenaMunich — home stadium of FC Bayern Munich
  • Heathrow AirportLondon
  • Frankfurt AirportFrankfurt am Main, Germany
  • …and many more
Download portfolio PDF, 1.7 MB, in Ukrainian
Modern building with a curved glass facade Glass high-rise office tower

CFD modelling

Modelling jet fan smoke extraction and ventilation systems

We calculate airflow velocity and direction, temperature distribution, age of air and smoke spread in the car park to confirm the system works as designed.

Airflow streamlines
Smoke spread, 3D model
Air velocity, m/s
Local mean age of air, s
Temperature during a fire, °C
Temperature distribution
Air velocity vectors

Wolter products

Fans for ventilation and smoke extraction

Wolter products have proven themselves in virtually every area of ventilation and air conditioning for residential, commercial and public buildings.

AXG

Two-stage axial fans

Two counter-rotating stages with separate motors reach about 3,500 Pa. If one stage stops, the other still delivers around 65% of the airflow, so car park extraction keeps running.

GAES / GADS

Garage extract fans

Two independent fans in one duct housing, fully separated as garage regulations require, with backdraft dampers and fully variable speed.

Full range

The standard range ships from stock at short notice.

  • Fans for rectangular ductsEKN, DKN, EKNS, DKNS
  • Roof fansRH, RV, RVS
  • Axial fans for rectangular ductsEK, DK, EKS, DKS
  • Roof fans with external motorRVH
  • Fans for circular ductsRFE, RF, RS, RK
  • Centrifugal fansERSE, ERSD, DRSE, DRSD
  • Sound-insulated circular duct fansSDB
  • Centrifugal fans with standard motorTNF, HNF, TNQ, HNQ
  • Axial fans in cylindrical housingAXV, BXV
  • Chemically resistant centrifugal fanCHEM
  • Two-stage axial fansAXG
  • Extract boxes for polluted air (kitchens)KAF, KAT
  • Axial fansAER, AEQ, ADR, ADQ
  • Cabinet fansGAB, GAPF, KB, KBPF
  • Garage extract fansGAES, GADS
  • Control components—

About Wolter

German engineering since 1971

When developing its products, Wolter pays close attention to aerodynamics, control technology, and the acoustic and vibration behaviour of ventilation equipment.

Wolter GmbH Maschinen- und Apparatebau KG has designed and manufactured fans since 1971. The company serves key markets worldwide through subsidiaries and distributors, and around 80% of its turnover comes from exports.

The complex interplay between these factors in every new project is always of great interest to the company’s engineers. Using the most innovative design tools, including CFD simulation, Wolter offers the optimal solution for any task.

Modern drive and control technology increases efficiency and significantly reduces a building’s operating costs. Aerodynamically optimised impellers and housings keep noise to a minimum.

  • Two factories in Germany, headquarters in Malsch
  • Quality management system certified to DIN EN ISO
  • In-house facilities for factory testing, research and development
  • First manufacturer to put carbon-fibre axial impellers into series production
Where Wolter equipment is used Building ventilationSmoke exhaustCar parksTunnelsIndustryMarine
Manufacturer’s website: wolter.eu
Wolter factory in Germany, production and engineering
Wolter

Contact

Tell us about your project

We’ll select the equipment, prepare a solution and, if needed, run a CFD simulation.

Jetfans · NEXTAIR LLC

Send us a message

Clicking Send opens your e-mail app with the message ready to go.